{"product_id":"pdu-tripp-lite-monofasico-controlable-switch-transferencia-automatica-1-9kw-entradas-15-20p-5-20p-120v-16-tomacorrientes","title":"Tripp Lite Single-Phase Switched PDU with Automatic Transfer Switch, 1.9kW, 15-20P\/5-20P Inputs, 120V, 16 Outlets","description":"\u003cdiv id=\"sync-description\" data-source=\"db-sync\"\u003e\n  \u003cp\u003eTripp Lite's Controllable Automatic Transfer Switch (ATS) PDU provides a redundant power option for single-corded network devices. Dual power cords support separate connections to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary power cord. If the primary power source becomes unstable or fails altogether, the ATS will switch to the secondary power source until the primary input is re-established and stable. Built-in network management interface card with LX Platform.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"sync-icecat\" data-source=\"db-sync\"\u003e\n  Tripp Lite’s Controllable Automatic Transfer Switch (ATS) provides a redundant power option for single-corded network devices. Dual power cords support separate connections to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary power cord. If the primary power source becomes unstable or fails altogether, the ATS will switch to the secondary power source until the primary input is re-established and stable. Built-in LX Platform network management interface card. The Java-free HTML5-based LX Platform interface enables full remote access to monitor PDU status and send email notifications via secure Web browser, SNMP, telnet or SSH. It allows 10Mbps\/100Mbps auto-sensing for optimal communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Supported protocols include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. Controllable PDU features include individually controllable outlets and built-in network interface. Super-fast switching between primary and secondary sources occurs in milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant network power applications. It allows fault-tolerant hot-swap UPS protection when used with a single UPS and fully redundant protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be backed up by a permanent sine wave UPS with zero transfer time. Tripp Lite's SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations using main circuits, backup generators and even separate utility power feeds are fully supported. The ATS's internal processor constantly evaluates power quality on both power sources to prevent transferring to a secondary source when it is unavailable or of lower quality than the primary source. Input LEDs on the front panel display primary or secondary power availability.\u003cbr\u003e\u003cbr\u003e• 120V 20A Power Distribution Unit (PDU) with LX Platform network interface, Automatic Transfer Switch (ATS) and controllable outlets (Agency derated to 16A)\u003cbr\u003e• Provides a redundant A\/B power option for non-redundant, single-power cord network equipment\u003cbr\u003e• Controllable PDU features allow programmable or real-time power control of individual outlets via the integrated network interface\u003cbr\u003e• Digital display continuously reports output power consumption in Amps\u003cbr\u003e• 16 NEMA 5-15\/20R controllable outlets\u003cbr\u003e• 1U horizontal rackmount form factor; 36.8 cm [14.5\"] deep\u003cbr\u003e• Set of two 3.66 m [12 ft.] NEMA L5-20P power cords with set of two 5-20P adapters allow connection to separate PRIMARY and SECONDARY power feeds\u003cbr\u003e• ATS circuits maintain power output from the primary power cord. When primary power fails or becomes unstable, the ATS will switch to maintain output from the secondary power cord until primary power is restored and stable\u003cbr\u003e• ATS configurations allow fault-tolerant hot-swap UPS protection when used with a single UPS and fully redundant UPS protection when each power cord connects to a separate UPS system (in a two-UPS environment, the primary power cord must be supported by an online UPS with zero transfer time, similar to Tripp Lite's SmartOnline series)\u003cbr\u003e• Advanced ATS configurations using main circuits, backup generators and even separate out-of-phase utility power feeds are fully supported\u003cbr\u003e• The ATS's internal processor constantly evaluates power quality on both feeds to prevent transferring to the secondary source when it is unavailable or of lower quality than the primary source\u003cbr\u003e• Super-fast switching between primary and secondary sources occurs between 2 and 7 milliseconds\u003cbr\u003e• The LX Platform interface enables full remote access for easy power monitoring with email notifications via secure Web browser, SNMP, telnet or SSH. DHCP \/ Manual configuration supported\u003cbr\u003e• 10Mbps \/ 100Mbps Auto-Sensing\u003cbr\u003e• Real-time clock backup maintains the time of day and date even if the PDU is powered off.\u003cbr\u003e• Email warning notifications or SNMP traps provide immediate notification of an event\u003cbr\u003e• Firmware upgrade capability allows for future product enhancements\u003cbr\u003e• Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities\u003cbr\u003e• Outlets are factory programmed for sequential power-on at 250 millisecond intervals when the PDU is initially energized\u003cbr\u003e• LEDs on the front panel confirm power availability on both power lines\n\u003c\/div\u003e\n\u003cdiv id=\"sync-specs\" data-source=\"db-sync\"\u003e\n  \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n  \u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\u003cth colspan=\"2\"\u003eGeneral Features\u003c\/th\u003e\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTripp Lite\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eItem\u003c\/td\u003e\n\u003ctd\u003ePDU\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePDU Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic Transfer Switch; Controllable\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePDU Input Voltage\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecommended Electrical Service\u003c\/td\u003e\n\u003ctd\u003eTwo 20A 120V single-phase circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMaximum Input Amperage\u003c\/td\u003e\n\u003ctd\u003e\t16\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMaximum Input Amperage Details\u003c\/td\u003e\n\u003ctd\u003eAgency derated to 16 A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection Type\u003c\/td\u003e\n\u003ctd\u003ePrimary: L5-20P and Secondary: C20 input and detachable C19 to L5-20P cable and adapters\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePDU Plug Type\u003c\/td\u003e\n\u003ctd\u003e(2) NEMA 5-20P; (2) NEMA L5-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Phase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Cable Details\u003c\/td\u003e\n\u003ctd\u003eThe set of 2 L5-20P cables with two 5-20P adapters allows separate connection of PRIMARY and SECONDARY power sources\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity Details\u003c\/td\u003e\n\u003ctd\u003eTotal capacity of 1.92kW (120V) \/ 16A; 16A maximum per outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eFrequency Compatibility\u003c\/td\u003e\n\u003ctd\u003e50Hz \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutlets\u003c\/td\u003e\n\u003ctd\u003e(16) 5-15\/20R\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage (V~)\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eFront Panel LCD Display\u003c\/td\u003e\n\u003ctd\u003eDigital display reports total PDU output current in amperes\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSwitches\u003c\/td\u003e\n\u003ctd\u003eRecessed reset button to reset the SNMP management card without affecting AC output to connected equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eConstruction Material\u003c\/td\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSupported Form Factors\u003c\/td\u003e\n\u003ctd\u003e\t1U Rackmount\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePDU Form Factor\u003c\/td\u003e\n\u003ctd\u003eHorizontal (1U)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e58.17 cm x 52.58 cm x 13.72 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.07 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e","brand":"TRIPP LITE","offers":[{"title":"Default Title","offer_id":48213351760097,"sku":"PDUMH20ATNET","price":11524.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/9493\/9617\/files\/TRVSUPAB060_zoom.jpg?v=1779150745","url":"https:\/\/directob2b.com\/en\/products\/pdu-tripp-lite-monofasico-controlable-switch-transferencia-automatica-1-9kw-entradas-15-20p-5-20p-120v-16-tomacorrientes","provider":"Directo B2B","version":"1.0","type":"link"}