{"product_id":"ups-tripp-lite-smartonline-en-linea-de-doble-conversion-2u-2kva-para-instalacion-en-rack","title":"Tripp Lite Smartonline Double-Conversion On-Line 2kVA 2U Rackmount UPS","description":"\u003cdiv id=\"sync-icecat\" data-source=\"db-sync\"\u003e\n  Tripp Lite SmartOnline UPS systems offer high-performance power protection; ideal for servers and network equipment in data centers, computer rooms, and network wiring closets. Double-conversion online uninterruptible power supply (UPS) system, with transformerless IGBT technology, maintains perfectly regulated power output by converting raw AC input to DC and then reconverting it to AC output. Fully regulated sine wave AC output with +\/-2% voltage regulation continuously powers network equipment, even during severe voltage sags or surges, all without depleting the UPS's battery reserves. Maintains battery-derived AC output during power outages with zero transfer time. Extended runtime option available. The interactive LCD interface informs about UPS operating mode, detailed UPS and site power data, and allows for a variety of UPS calibration and configuration options. Extremely efficient operation in optional economic mode decreases heat emission and produces energy cost savings. Network management interfaces support communications via USB, RS-232, contact closure, and a slot for network management interface options. The built-in DB9 port offers enhanced RS-232 data monitoring and basic contact closure capability. The HID-compliant USB interface allows integration with Windows and Mac OS X built-in power management and automatic shutdown features. PowerAlert monitoring software can be downloaded for free. Emergency Power Off (EPO) interface. LED group indicates UPS operating mode, utility power availability, battery mode operation, inverter operation, ECO mode status, and output power availability. The LED\/LCD display panel can be easily rotated for viewing in rack or tower configurations. Audible alarm with momentary button alarm cancellation options and LCD configuration for silent mode. Programmable self-diagnosis. Fault-tolerant automatic bypass mode. Independent battery restart. Hot-swap internal batteries and external battery packs can be replaced in the field.\u003cbr\u003e\u003cbr\u003e• SU2200RTXLCD2U - Tripp Lite online, double-conversion, 2U rack or tower UPS. Capacity 2200VA \/ 2.2kVA \/ 1800W\u003cbr\u003e• Transformerless IGBT technology\u003cbr\u003e• Selectable 100\/110\/120\/127V output (factory set to 120V)\u003cbr\u003e• NEMA 5-20P input; 6 5-15\/20R and 1 L5-20R outlets\u003cbr\u003e• Two controllable load banks with 3 outlets support programmable load restart or disconnection options\u003cbr\u003e• Allows output voltage regulation within 2% and zero transfer time in double-conversion mode\u003cbr\u003e• Eco mode configuration option offers improved efficiency, reduced power consumption, and lower heat emissions.\u003cbr\u003e• 12 minutes runtime at 50% load (900W) and 4 minutes at 100% load (1800W) with internal batteries\u003cbr\u003e• External battery modules available BP48V24-2U (1 limit), BP48V60RT-3U (multiple modules supported) and BP48V27-2US (multiple modules supported) (some configurations require Tripp Lite External Battery Configuration Software)\u003cbr\u003e• Smart battery management system with temperature compensated charging extends battery life\u003cbr\u003e• LCD interface reports operating mode plus 9 selectable UPS data screens (% and kW load, % and kVA load, power factor, input volts and hertz, output volts and hertz, battery volts and charge %, runtime minutes, remaining capacity, Kw\/h consumption).\u003cbr\u003e• In addition, the LCD interface supports 16 UPS configuration screens and software configuration options\u003cbr\u003e• 4 rackmount hardware posts are included, optional 2POSTRMKITWM allows 2-post rack installation, optional 2-9USTAND allows tower placement\u003cbr\u003e• Surge suppression for a phone\/network line\u003cbr\u003e• Electronic bypass maintains utility power output during various UPS fault conditions\u003cbr\u003e• Battery-independent restart ensures automatic UPS power-up, without user intervention, after prolonged outages, even with expired batteries that need replacement.\u003cbr\u003e• Frequency regulation \/ conversion mode offers generator-compatible frequency correction or frequency conversion from 50 to 60Hz or 60 to 50Hz\u003cbr\u003e• USB, RS-232, contact closure ports, and slot for network management card options\u003cbr\u003e• Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD, and RELAYIOCARD\u003cbr\u003e• HID-compliant USB interface allows integration with Windows and Mac OS X built-in power management and automatic shutdown features.\u003cbr\u003e• USB and Serial ports allow unattended shutdown and data saving when used with Tripp Lite PowerAlert software, available for FREE download from www.tripplite.com\/poweralert\n\u003c\/div\u003e\n\u003cdiv id=\"sync-specs\" data-source=\"db-sync\"\u003e\n  \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n  \u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\u003cth colspan=\"2\"\u003eGeneral Features\u003c\/th\u003e\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTripp Lite\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eArticle\u003c\/td\u003e\n\u003ctd\u003eUPS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSU2200RTXLCD2U\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eUPS Type\u003c\/td\u003e\n\u003ctd\u003eOnline\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003eInput Phase Single-Phase Specified Input Current (Maximum Load) 16 A Supported Nominal Input Voltage(s) 100V AC; 110V AC; 120V AC Nominal Input Voltage Description 120V factory default UPS Input Connection Type 5-20P UPS Power Cord Length (feet) 8 UPS Power Cord Length (m) 2.4 Recommended Electrical Service 120 V Plug Type 5-20P Input Current 16 A Power Factor (Input) 0.99\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eOutput Capacity (VA) 2000 Output Capacity (kVA) 2 Output Capacity (Watts) 1800 Output Capacity (kW) 1.8 Input 120V factory default UPS Input Connection Type 5-20P UPS Power Cord Length (feet) 8 UPS Power Cord Length (m) 2.4 Recommended Electrical Service 120 V Plug Type 5-20P Input Current 16 A Power Factor (Input) 0.99 AC Output Waveform (AC Mode) Pure Sine Wave AC Output Waveform (Battery Mode) Pure Sine Wave Supported Nominal Output Voltage(s) 100V; 110V; 115V; 120V; 127V Outlets (6) 5-20R; (1) L5-20R Individually Controllable Load Banks Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eBattery Type: Valve Regulated Lead Acid [VRLA], Full Load Runtime (min): 7.7 min (1800 W) Half Load Runtime (min): 20.2 min (900 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eFront Panel LCD Display\u003c\/td\u003e\n\u003ctd\u003eFront panel LCD information and configuration display offers detailed UPS and site power status data, plus voltage, frequency, operating mode, alarm function, and a variety of additional options settings\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Alarm\u003c\/td\u003e\n\u003ctd\u003eAudible alarm indicates UPS startup conditions, utility power failure, low battery, overload, UPS fault, and remote shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003e4 LED status indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePhysical\u003c\/td\u003e\n\u003ctd\u003ePrimary Form Factor For rack installation Rack Height 2U Cooling Method Fan Description of included installation accessories Includes accessories for 4-post rack installation Supported Installation Form Factors with Optional Accessories 19-inch 4-post rack installation Supported Installation Form Factors with Optional Accessories 2-post rackmount (RK2PC) Minimum Required Rack Depth (cm) 68.07 Notes on Optional Installation Accessories 2-post rail kit available, part no. RK2PC Shipping Dimensions (H x W x D \/ cm) 24.00 x 58.01 x 78.00 Shipping Weight (kg) 34.60 UPS Enclosure Material Metal Unit Weight (kg) 27.90\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e","brand":"TRIPP LITE","offers":[{"title":"Default Title","offer_id":48213450522849,"sku":"SU2200RTXLCD2U","price":25066.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/9493\/9617\/files\/TRVFUEAB067_zoom.jpg?v=1779150651","url":"https:\/\/directob2b.com\/en\/products\/ups-tripp-lite-smartonline-en-linea-de-doble-conversion-2u-2kva-para-instalacion-en-rack","provider":"Directo B2B","version":"1.0","type":"link"}