Tripp Lite Single-Phase Switched PDU with Automatic Transfer Switch, 1.9kW, 15-20P/5-20P Inputs, 120V, 16 Outlets
Tiempo estimado de entrega: 5 días hábiles (Nacional)
Usa el código “DB2B2026” para obtener un descuento del 15%
Envío gratis en compras mayores a $0,000.00 MXN
Garantizamos un pago seguro:
Características del producto
Tripp Lite's Controllable Automatic Transfer Switch (ATS) PDU provides a redundant power option for single-corded network devices. Dual power cords support separate connections to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary power cord. If the primary power source becomes unstable or fails altogether, the ATS will switch to the secondary power source until the primary input is re-established and stable. Built-in network management interface card with LX Platform.
• 120V 20A Power Distribution Unit (PDU) with LX Platform network interface, Automatic Transfer Switch (ATS) and controllable outlets (Agency derated to 16A)
• Provides a redundant A/B power option for non-redundant, single-power cord network equipment
• Controllable PDU features allow programmable or real-time power control of individual outlets via the integrated network interface
• Digital display continuously reports output power consumption in Amps
• 16 NEMA 5-15/20R controllable outlets
• 1U horizontal rackmount form factor; 36.8 cm [14.5"] deep
• Set of two 3.66 m [12 ft.] NEMA L5-20P power cords with set of two 5-20P adapters allow connection to separate PRIMARY and SECONDARY power feeds
• ATS circuits maintain power output from the primary power cord. When primary power fails or becomes unstable, the ATS will switch to maintain output from the secondary power cord until primary power is restored and stable
• ATS configurations allow fault-tolerant hot-swap UPS protection when used with a single UPS and fully redundant UPS protection when each power cord connects to a separate UPS system (in a two-UPS environment, the primary power cord must be supported by an online UPS with zero transfer time, similar to Tripp Lite's SmartOnline series)
• Advanced ATS configurations using main circuits, backup generators and even separate out-of-phase utility power feeds are fully supported
• The ATS's internal processor constantly evaluates power quality on both feeds to prevent transferring to the secondary source when it is unavailable or of lower quality than the primary source
• Super-fast switching between primary and secondary sources occurs between 2 and 7 milliseconds
• The LX Platform interface enables full remote access for easy power monitoring with email notifications via secure Web browser, SNMP, telnet or SSH. DHCP / Manual configuration supported
• 10Mbps / 100Mbps Auto-Sensing
• Real-time clock backup maintains the time of day and date even if the PDU is powered off.
• Email warning notifications or SNMP traps provide immediate notification of an event
• Firmware upgrade capability allows for future product enhancements
• Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities
• Outlets are factory programmed for sequential power-on at 250 millisecond intervals when the PDU is initially energized
• LEDs on the front panel confirm power availability on both power lines
Technical Specifications
| General Features | |
|---|---|
| Brand | Tripp Lite |
| Item | PDU |
| PDU Type | Automatic Transfer Switch; Controllable |
| PDU Input Voltage | 120 |
| Recommended Electrical Service | Two 20A 120V single-phase circuits |
| Maximum Input Amperage | 16 |
| Maximum Input Amperage Details | Agency derated to 16 A continuous |
| Input Connection Type | Primary: L5-20P and Secondary: C20 input and detachable C19 to L5-20P cable and adapters |
| PDU Plug Type | (2) NEMA 5-20P; (2) NEMA L5-20P |
| Input Phase | Single-phase |
| Input Cable Details | The set of 2 L5-20P cables with two 5-20P adapters allows separate connection of PRIMARY and SECONDARY power sources |
| Output Capacity Details | Total capacity of 1.92kW (120V) / 16A; 16A maximum per outlet |
| Frequency Compatibility | 50Hz / 60Hz |
| Outlets | (16) 5-15/20R |
| Nominal Output Voltage (V~) | 120V |
| Overload Protection | Not applicable |
| Front Panel LCD Display | Digital display reports total PDU output current in amperes |
| Switches | Recessed reset button to reset the SNMP management card without affecting AC output to connected equipment |
| Construction Material | Steel |
| Supported Form Factors | 1U Rackmount |
| PDU Form Factor | Horizontal (1U) |
| Dimensions | 58.17 cm x 52.58 cm x 13.72 cm |
| Weight | 9.07 kg |
Características generales
|
Dimensiones 58.17 cm x 52.58 cm x 13.72 cm |
Modelo |
|
Garantía |
Empaquetado
|
Ancho: 123mm |
Embalaje: Caja de cartón |
|
Profundidad: 380mm |
Altura: 235mm |